2021
THE EVALUATION OF THE LEVEL OF AGREEMENT BETWEEN TWO BLIND, NON-EXPERIENCED OBSERVERS IN THE ANALYSIS OF THE ECHOGENICITY INDEX IN ULTRASOUND B-IMAGES OF THE THYROID GLAND
BLAHUTA, Jiří, Jan LAVRINČÍK, Lukáš PAVLÍK, Zuzana REPASKÁ, Tomáš SOUKUP et. al.Základní údaje
Originální název
THE EVALUATION OF THE LEVEL OF AGREEMENT BETWEEN TWO BLIND, NON-EXPERIENCED OBSERVERS IN THE ANALYSIS OF THE ECHOGENICITY INDEX IN ULTRASOUND B-IMAGES OF THE THYROID GLAND
Autoři
BLAHUTA, Jiří (203 Česká republika, domácí), Jan LAVRINČÍK (203 Česká republika, domácí), Lukáš PAVLÍK (203 Česká republika, domácí), Zuzana REPASKÁ (203 Česká republika, domácí) a Tomáš SOUKUP
Vydání
Hradec Králové, MMK 2021, Mezinárodní Masarykova konference pro doktorandy a mladé vědecké pracovníky, od s. 957-964, 8 s. 2021
Nakladatel
Magnanimitas, Hradec Králové
Další údaje
Jazyk
angličtina
Typ výsledku
Stať ve sborníku
Obor
10201 Computer sciences, information science, bioinformatics
Stát vydavatele
Česká republika
Utajení
není předmětem státního či obchodního tajemství
Forma vydání
elektronická verze "online"
Organizační jednotka
Moravská vysoká škola Olomouc
ISBN
978-80-87952-35-1
Klíčová slova anglicky
thyroid gland ultrasound; ultrasound image processing; echogenicity index; Bimages; endocrinology ultrasound
Štítky
Změněno: 29. 4. 2022 13:12, Ing. Michaela Nováková
Anotace
V originále
Recently, the authors have published studies focused on the echogenicity index analyzed in ultrasound B-images using own software designed to analysis of ultrasound B-images, developed since 2012. The studies have been focused on selected brain structures and the echogenicity index was firstly used in analysis of atherosclerotic plaques using B-imaging. The almost perfect reproducibility between two blind observers was confirmed. In this study focused on B-imaging of the thyroid gland, the authors analyze the reproducibility of the echogenicity index in a free-hand Region of Interest of the thyroid gland tumor. Overall, 102 images were processed. Both of the observers are non-experienced in sonography; the main goal of this study is to ascertain the level of agreement between results when the same ROI is used. The results repeatedly ascertained the almost perfect level of agreement of the echogenicity index for ultrasound B-images analysis in different structures. The correlation coefficient r=0.98 and the average absolute error between echogenicity index values is under 15 %. In this phase, the clinical point of view is not evaluated; only the reproducibility of the echogenicity index is judged. The echogenicity index will be analyzed to see if there is any relation between the echogenicity index and tumor type. All achieved results will be checked by an experienced sonographer for future clinical studies